terawall
gold
TWALL GOLDcol 000
Thermal-acoustic insulation with 25, 50, 75 or 100 mm thick rolled sheet.
The quilted sheet is composed of three layers: the first layer consists of a 200 gsm E glass cloth and pure aluminium; the second consists of various thicknesses of anti-dusting C glass wool (formaldehyde-free, free of non-fibrous material, odourless, mould-resistant, parasite-resistant and rodent-resistant); the third layer is made of a special felt-like 120 gsm Carbon Fiber. The layers are quilted together lengthwise using a 100% Kevlar thread without the use of adhesives. Class A2-s1, d0 fireproof recyclable product.
Suitable for thermal and acoustic insulation of walls, drywalls and brick walls, as well as various suspended ceiling systems.
customs code
XXX
features
carbon fiber felt,
25/50/75/100 mm fiberglass C type,
fiberglass fabric E type,
row alluminium,
kevlar.
panel dimension
25 mm thickness
60 x 2000 cm (12 m²)
120 x 2000 cm (24 m²)
50 mm thickness
60 x 1200 cm (7,2 m²)
120 x 1200 cm (14,4 m²)
75 mm thickness
60 x 900 cm (5,4 m²)
120 x 900 cm (10,8 m²)
100 mm thickness
60 x 900 cm (5,4 m²)
120 x 900 cm (10,8 m²)
weight
25 mm = 0,90 kg/m²,
50 mm = 1,30 kg/m²,
75 mm = 1,50 kg/m²,
100 mm = 2,60 kg/m².
thickness
25 / 50 / 75 /100 mm.
dimensional tolerance
± 5 %, EN 822.
sustainability
CE.
thermal conductivity
ƛ 0,026 W/mk, EN 12667.
acustic insulation
Rw 26 dB, (50 mm thick board), ISO 10140.
sound absorbtion
A type mounting
Ɑw 0,70, ISO 354.
E-250 type mounting
Ɑw 0,80, ISO 354.
water vapor diffusion resistance factor µ
7, EN 12086.
short term water absorption
1 kg/m³, EN 1609.
declared thermal resistance
values connected to thickness
25 mm = RD 0,96 m³K/W,
50 mm = RD 1,92 m³K/W,
75 mm = RD 2,88 m³K/W,
100 mm = RD 3,84 m³K/W.
formaldehyde emissions
< 0,1 ppm (0,124 mg/m³) no release, ISO 1600-9.
fire resistance
A2 s1,d0 - EN 13501.